Blog
Phone : 847-309-2818 M-F 10am-5pm

BLOG

Keyword:

Stairmaster Treadmills 510, 612 Controller keys

Apr 03, 2022

Please check the attached pdf - Stairmaster Treadmills 510, 612 Controller keys...

read more

Stairmaster Spped/Grade (open-loop mode, club track 510-612 only)

Apr 03, 2022

This feature records any error condition and the distances(in miles) when the error occurred. In case of multiple errors, only one is logged. If the distance has not been incremented from the last error, new errors will not be logged until the belt has been started and stopped(Stopping logs the distance). The display will log eight of the most recent events from the top down. When the ninth error ...

read more

Stairmaster Treadmills 510, 612 Heart Rate Monitoring

Apr 03, 2022

The Polar telemetry system for heart rate detection and transmission has been time-tested and shown to be accurate and reliable; however, there is a small percentage of people for whom the system will not work. If all the steps in the table from pdf are performed and the belt and controller appear to be operating correctly, the user's heart rate may not be detectable by the system. Please check ...

read more

Stairmaster Treadmills 510, 612 Error codes

Apr 03, 2022

Please check the attached pdf - Stairmaster Treadmills 510, 612 Error codes...

read more

Stairmaster Treadmills C40 Console Upgrade

Apr 03, 2022

C40 Controller Upgrade Kit installation instructions for the ClubTrack® 510 and ClubTrack 612 Treadmills. Please check the attached pdf for details...

read more

Precor Error Code OBS Obstruction Sensor

Mar 19, 2022

Applies to SCL800 Issue Symptoms The Obstruction error alerts the user that something is blocking the OBS sensors. When detected, the machine immediately slows to a stop and the "OBS Obstruction Detected" message is displayed. Typically an object is blocking the IR beam between the emitter and receiver OBS sensors. Other causes could include dirty sensor IR lens or a faulty damaged...

read more

Precor Error Code E2 Lift Error

Mar 19, 2022

Applies to 9.23, 9.27, TR211, TRM200-14 treadmills Issue symptoms This error is shown in the console TIME window indicating an incline problem. This error will occur if the incline is unable to move or if the incline position potentiometer is not functioning. When the E2 error occurs, all drive motor and lift motor motion stops and the display is blank except for the error display. ...

read more

Precor Error Code 55 Holding Brake Manual Release Detected

Mar 19, 2022

Applies to SCL800 Issue Symptoms Error 55 occurs when a workout is started and the Holding Brake Lever is in the OFF "Released" position. The Holding Brake Lever must be in the ON "Normal" position to start a workout. The LPCA detects that the Holding Brake Manual Release lever switch signal is continuously in the Manual Release active state for longer than 5 seconds. The most ...

read more

Precor Error Code 53 Holding Brake Slipping

Mar 19, 2022

Applies to SCL800 Issue Symptoms Error 53 means the Holding Brake has slipped when it should not. This error occurs when the LPCA detects the stairs moving while machine is STOPPED and the Holding Brake is engaged. The holding brake should not allow the stairs to slip or move when stopped or the power is switched OFF. This error triggers when the either the Holding Brake is engaged ...

read more

Precor Error Code 52 Resistance Brake Current High HW

Mar 19, 2022

Applies to SCL800 Issue Symptoms Hardware version of Error 50, see 50  . The LPCA Hardware has detected that the Resistance Brake Current was too High. Too much current is being fed to the Resistance Brake resulting in the holding brake engaging. Error 52 triggers when the Resistance brake current is continuously greater than 2 Adc for longer than 410 ms. This event...