Precor Error Code 57, 58 Generator Voltage Too Low or High

Jan 27, 2022

Applies to Chrono(Spinner Chrono Power bike) bike Issue symptoms Generator voltage is or has been detected as too low (Error 57) or too high (Error 58). These errors are only detected or cleared while pedaling above 35 RPM. May be a temporary condition due to some rider pedaling modalities. Troubleshooting steps Run the Generator Voltage service test to verify that there is ...

read more

Precor Error Code 63 High RPM

Jan 27, 2022

Applies to Chrono(Spinner Chrono Power Bike)   Issue symptoms RPM is or has been detected as too high. The RPM is measured from one of the three, time-varying AC(Alternating Current) phases from the generator (pin 3). May be a temporary condition due to some rider pedaling modalities. Troubleshooting steps Use the RPM service test to measure the real-time RPM while ...

read more

Precor Error Code 62 Vertical Sensor Failure

Jan 27, 2022

Applies to AMT12, all models Issue symptoms Error 62 will occur when the vertical stride is not detected. The most likely cause is a faulty, broken, or poor cable connection at the lower PCA(Printed Circuit Assembly). A missing or reversed magnet on the crank arm is also possible, as is a defective sensor. Least likely but possible is a fault on the lower PCA. Troubleshooting steps...

read more

Pacemaster gold elite giving error code 133

Jan 23, 2022

Symptoms:  Pacemaster gold elite giving error code 133. Checked all connections so far and continuity through wire connecting top and bottom boards. No luck Answers: Please reset the treadmill, follow this steps and fix it. 1. Unplug the treadmill. Locate the console key and place the safety or reset key into the treadmill console. Replace any parts that need replacing, or is ...

read more

Precor Error Code 60, 61 Auto Stop Not Working/Present

Jan 23, 2022

Applies to These errors are associated with the TRM10(TRM800 version 1 treadmills mfg. dates 2010 thru 2014.) Treadmill. The Auto Stop feature was not on the TRM as a standard feature until 12/28/2010 but may have shipped with a P80 console before 12/28/2010. These errors will only be present when the Auto Stop function is Enabled in the Club Settings/Workout Limits. When the Auto Stop ...

read more

Treadmill stops When You're on it. But only sometimes it works???

Jan 22, 2022

Symptoms:  Long days after you started using your Treadmill. The Treadmill runs with you running on it or walking on it and then every once in awhile it's stopped. then when you get off of it, The belt starts moving again. if you step back on it stops again.  Usually the answer is turning it off and restarting it then it runs again. You can guess it's not the motor since it works ...

read more

Precor Error Code 42 Lift Position Out of Range

Jan 16, 2022

Applies to All machines with a Lift Motor Issue symptoms The software on the lower PCA(Printed Circuit Assembly) expects the A/D(analog to digital converter) value from the lift potentiometer is within a certain range, low to high. If the A/D value goes outside this range, an Error 42 will be displayed. The most likely cause of this error is the motor moving further than it should or jamming...

read more

Precor Error Code E4 Incomplete Initialization

Jan 16, 2022

Applies to 9.23, 9.27, TRM211, and TRM200-14 treadmills Description This error is shown in the console TIME window indicating an incomplete upper PCA(Printed Circuit Assembly) to lower PCA initialization has occurred. When the E4 error occurs, all drive motor and lift motor motion stops and the display is blank except for the error display. Troubleshooting steps Run the initialization ...

read more

Precor Error Code ERR EEPROM Problem

Jan 16, 2022

Applies to 9.23, 9.27, TRM211, and TRM200-14 treadmills Issue symptoms This error is shown in the console TIME window when the EEPROM is damaged or unable to retrieve or store data. When the Err error occurs, all drive motor and lift motor motion stops and the display is blank except for the error display. When this error occurs consistently, it indicates an upper PCA(Printed Circuit ...

read more

Precor Error Code LS Speed Sensor Signal Missing

Jan 16, 2022

Applies to 9.23, 9.27, TRM211, and TRM200-14 treadmills Issue symptoms This error is shown in the console TIME window when the drive motor speed signal is not received from the speed sensor for eight (8) consecutive seconds. When the LS error occurs, the drive motor and lift motor motion stops and the display is blank except for the error display. The treadmill uses a reed switch and two ...

read more